Showing posts with label Connectors. Show all posts
Showing posts with label Connectors. Show all posts

Thursday, April 11, 2013

[OpsMgr 2012 SP1 UR2] System Center Advisor Connector for Operations Manager Preview


The Advisor Connector provides Operations Manager users with configuration analysis for their computers.


Quick details

Version:1.0                            Date published:4/8/2013
Language:English
File nameSize
SC Advisor Connector for OM Preview.msi          1.2 MBDownload



Overview

The System Center Advisor Connector for Operations Manager preview enables Operations Manager users to receive ongoing assessment of configuration for their windows computers. After installing the connector and selecting computers to be analyzed, Operations Managers users will be able to receive Advisor alerts in the Operations Manager console.


System requirements

Supported operating systems:            Windows Server 2012
This Preview requires Operations Manager 2012 SP1 with Update Rollup 2 installed.
Complete Operations Manager system requirements can be found at : http://technet.microsoft.com/en-us/library/jj656654.aspx


Instructions

In order to install the Advisor Connector preview:
  1. Download the MSI provided in this page
  2. Extract the contents to a folder in your computer
  3. Import the extracted MPBs into the Operations Manager Console
For more information on configuring the Advisor Connector Preview, visit the Advisor Online Help at:
http://go.microsoft.com/fwlink/?LinkId=293793

You can also ask questions and learn more about Advisor at our blog:
http://blogs.technet.com/b/momteam/archive/2013/04/09/system-center-advisor-connector-for-operations-manager-preview.aspx



This posting is provided "AS IS" with no warranties.

Thursday, January 10, 2013

[Orchestrator 2012] Orchestrator (SCORCH) 2012 Reference Guides

Eswar Koneti has posted on his blog today an interesting page related to Orchestrator 2012. He has listed out all the SCORCH guides integrated with Configuration manager 2012 to make us able to start building our SCORCH environment to integrate with System center products(Configmgr 2012).






A quick summary of the different link posted :

Start with the TechNet Documentation and the SCORCH Standard Activities.

System Center Orchestrator 2012: An Overview Video
Orchestrator 2012: a quick start deployment guide from Kelvin Holman

List of Step by Step series guides on Over View ,installation,runbook etc.

Integrated with System Center Configuration Manager (configmgr) 2012:


From my part, I would add a link to technet on How to Create an Orchestrator Connector that can be usefull.


This posting is provided "AS IS" with no warranties.

Monday, October 1, 2012

[OpsMgr 2007 R2][OpsMgr 2012] How to remove old product connectors from System Center Operations Manager

Removing an old product connector from System Center Operations Manager may be necessary if the product connector is no longer used in the environment. There is no Delete option in admin console UI for product connectors so the script below can be used to achieve the desired results.

Microsoft Support bring us a powershell script to do it in KB2626670 in Operations Manager 2007 R2 



Usage: OpsMgr2007-DeleteConnector.ps1 para1 para2
  • para1: Connector Name
  • para2: MS name, Optional, default value: localhost

In order to be able to remove an old connector in Operations Manager 2012,  has modified the script on his post >>>   Here   <<<



Usage: OpsMgr2012-DeleteConnector.ps1 para1 para2
  • para1: Connector Name
  • para2: MS name, Optional, default value: localhost



 

This posting is provided "AS IS" with no warranties.

Friday, September 28, 2012

[OpsMgr 2012] System Center 2012 Operations Manager – Alert Update Connector

The Alert Update Connector can set/override custom field values, owner, and/or ticket id for alerts

Version:1.0         Date published:9/27/2012


File name
Size
SCOM2012_AlertUpdateConnector.msi406 KBDownload


Overview

The Alert Update Connector can modify alert custom fields with additional information useful for situations like controlling alert forwarding to incident management systems and help reduce noise in the incident creation process.

Feature Summary:
  • Specify custom field values, owner, and ticket id for alerts generated by monitors
  • Override custom field values, owner, and ticket id for alerts generated by rules

System requirements

Supported operating systems: Windows Server 2008 R2
System Center 2012 Operations Manager Management Server or Console (The Alert Update Connector requires the System Center Operations Manager SDK)

Instructions

  1. Click on the link to the right, and download SCOM2012_AlertUpdateConnector.msi
  2. On a computer with System Center Operations Manager 2012 Management Server or Console installed, click on the MSI to extract the connector files
  3. Navigate to the folder/directory where the connector files are extracted to and open AlertUpdateConnector.rtf
  4. Follow the instructions in AlertUpdateConnector.rtf to install and configure the connector

This posting is provided "AS IS" with no warranties.

Tuesday, June 26, 2012

[OpsMgr 2012] A New XML Connector for SCOM 2012

Orchestrator is the tool everyone should use to export/Import Alerts from Operations Manager 2012 SDK and of course there is a reason of why Microsoft does not deliver a connector as they did with 2007.

Read more on http://blog.coretech.dk/kra/a-new-xml-connector-for-scom-2012/

This posting is provided "AS IS" with no warranties.

Tuesday, May 29, 2012

[OpsMgr 2007R2] System Center Operations Manager 2007 R2 Connectors & Cumulative updates KB2274165

It's not really a new link - Microsoft has published this in 2009 but I had to retrieve this information for my own work and I would like to share it on my blog.

Direct link : >>>>> Here <<<<<

The System Center Operations Manager 2007 R2 Connectors provide System Center Operations Manager 2007 R2 alert forwarding to remote systems, such as an Enterprise Management System (EMS) or service desk system.


Version:1.0                    Date published:7/24/2009

File nameSize
SCInterop_R2_RTM.exe188.8 MBDownload


Overview

Operations Manager 2007 R2 Connectors provide Operations Manager 2007 R2 alert forwarding to remote systems, such as an Enterprise Management System (EMS) or a service desk system. After Operations Manager 2007 R2 forwards an alert to a remote system, that alert data is synchronized throughout the lifetime of the alert. The result of that data synchronization is a robust and seamless systems management environment. Such an environment enables cross-organization support processes to take advantage of the resources and strengths of formerly independent support groups. The ultimate effect is improved enterprise systems health through improved organizational communication.

Sharing data between Operations Manager 2007 R2 and remote systems enables enterprise correlation of events from Windows-based systems, hardware, network, and UNIX and Linux systems. Correlating these events allows IT staff to determine the causes of issues and reduce the time to resolution of IT outages.

Synchronization of data between Operations Manager 2007 R2 and remote systems also enables operational groups to use familiar management interfaces. Users update an alert by using their management tool, and the data is updated in tools that are used by other operational groups.

This release of the Operations Manager 2007 R2 Connectors includes the following Connectors:
  • Microsoft System Center Operations Manager 2007 R2 Connector for IBM Tivoli Enterprise Console
  • Microsoft System Center Operations Manager 2007 R2 Connector for HP OpenView Operations for Unix
  • Microsoft System Center Operations Manager 2007 R2 Connector for HP OpenView Operations for Windows
  • Microsoft System Center Operations Manager 2007 R2 Connector for BMC Remedy ARS
  • Microsoft System Center Operations Manager 2007 R2 Universal Connector

Feature Summary:
  • Operations Manager 2007 R2 alerts are forwarded to a remote system.
  • Operations Manager 2007 R2 alerts are synchronized with remote systems throughout the lifetime of the alert.
  • Failover to backup remote system servers is supported.
  • The High Availability feature supports failover to secondary Connectors that are installed on other servers in the Operations Manager 2007 R2 domain.
  • Multiple Operations Manager 2007 R2 management groups that are communicating with a single remote system are supported.
  • Multiple different remote systems can be supported with multiple Connectors that are installed in one Operations Manager 2007 R2 management group.
  • Delivery of Operations Manager 2007 R2 alerts is guaranteed by requiring acknowledgement from remote systems.
  • The Connector user interface that is integrated into the Operations Manager 2007 R2 console provides the following functionality:
    • Connector health status can be monitored in the Operations Manager 2007 R2 console by using Connector management packs.
    • Connector configuration is limited to Operations Manager 2007 R2 administrators.
    • Operations Manager 2007 R2 servers, remote system servers, and High Availability Connectors can be configured for communications.
    • Alerts forwarding is configured by selecting alert fields, mapping severity, and mapping resolution states to equivalents in a remote system.
    • Selected alerts can be forwarded manually from the Operations Manager 2007 R2 console.
    • The Operations Manager 2007 R2 Product Connector Subscription wizard allows automatic forwarding of Operations Manager 2007 R2 alerts.
    • The Product Connector Subscription wizard allows separate alert forwarding for multiple Connectors.

System Center Operations Manager 2007 R2 Connectors Cumulative Update 2 (KB2274165)

 Direct link >>>>> Here <<<<<

The Systems Center Operations Manager 2007 R2 Connectors Cumulative Update 2 is the second update for the System Center Operations Manager 2007 R2 Connectors.


Version:1.0Date published:7/30/2010

 
File nameSize
OM2007R2Connectors-KB2274165.exe62.5 MBDownload
ReadMe.rtf152 KBDownload


Overview

The System Center Operations Manager 2007 R2 Connectors Cumulative Update 2 includes the System Center Operations Manager 2007 R2 Connectors Update (KB975774) and additional bug fixes.

Feature Summary:
This updated release includes all features that were in the previous update release (KB975774) and additional fixes in this release:
  • Fixes for the following issues (in previous release KB975774):
    • Potential high CPU usage of HP OVO Event Consumer for Windows (scinteropd.exe)
      • The Scinteropd.exe process of HP OVO Event Consumer for Windows sometimes increases CPU usage to a very high level. This problem occurs only in System Center Operations Manager 2007 R2 Connectors for HP Operations Manager on Windows. It occurs in all language versions of the connectors.
    • Synchronization issue in HP OVO Connector
      • HP Operations Manager and System Center Operations Manager 2007 R2 may be in an asynchronous state when alerts are forwarded that have already been resolved. Open events are still present in HP Operations Manager even though the corresponding alerts in System Center Operations Manager 2007 R2 are already resolved.
    • Remedy connectors do not populate the Computer Name and Domain fields
      • When an alert is forwarded from System Center Operations Manager 2007 R2 to Remedy, the Computer Name field and the Domain field are left blank in the Remedy notes field. This issue occurs in the release version of System Center Operations Manager 2007 R2 Connector for Remedy 6.3 and Remedy 7.1.
    • Unresponsiveness of the Interop provider when an Enterprise Management Service (EMS) API call returns an error
      • The Interop provider may stop responding and not recover when an API calls to the EMS and returns an error.

        Note Usually, the API calls to Remedy.

        This issue typically occurs when large localized text strings in the Custom Field Alert properties are forwarded to Remedy. However, it can also occur with other properties.
  • Additional issues addressed in this release:
    • Added Support for Remedy 7.5
      • This update enables support for Remedy 7.5 with the Operations Manager 2007 R2 Connector for Remedy.
    • Added Support for HP Operations Manager for UNIX v9
      • This update enables support for HP Operations Manager for UNIX v9 with the Operations Manager 2007 R2 Connector for HP Operations Manager. The Connector supports HP Operations Manager for UNIX v9 on the following platforms:
        • HPUX 11i v3 Itanium
        • Solaris 10 SPARC
        • RedHat Enterprise Linux 5.2 x64
    • Incorrect dates are passed to the remote system by the connector
      • The Connector performs an incorrect date conversion and forwards the incorrect date to the remote system.
    • Product Knowledge is not forwarded when the locale is Canadian English
      • If the locale on the Operations Manager server is set to Canadian English, the Product Knowledge will not be forwarded from Operations Manager to remote system, even if it is configured to do so.

This posting is provided "AS IS" with no warranties.