Friday, June 7, 2013

[OpsMgr 2007R2] Operations Manager agents with teamed network adapters fail to be discovered and monitored

Operations Manager agents with teamed network adapters fail to be discovered and monitored


System Center Operations Manager 2007 R2 agent computers that utilize NIC teaming are not discovered or monitored and you see the following errors:
Log Name:       Operations Manager
Source:            Health Service Script
Date:               <date>
Event ID:          4001
Task Category: None
Level:              Error
Keywords:       Classic
User:              N/A
Computer:      <computerName>
Description: Microsoft.Windows.Server.NetwokAdapter.BandwidthUsed.ModuleType.vbs : The class name 'Win32_PerfFormattedData_Tcpip_NetworkInterface Where Name ='VLAN100:HP Network Team _1'' did not return any valid instances.  Please check to see if this is a valid WMI class name.. Invalid class
You may also see the following alert:
The process started at 09:44:43 failed to create System.PropertyBagData, no errors detected in the output. The process exited with 0
Command executed: "C:\Windows\system32\cscript.exe" /nologo "Microsoft.Windows.Server.NetwokAdapter.BandwidthUsed.ModuleType.vbs"
Working Directory: C:\Program Files\System Center Operations Manager 2007\Health Service State\Monitoring Host Temporary Files 23\\
One or more workflows were affected by this.
Workflow name: Microsoft.Windows.Server.2008.NetworkAdapter.PercentBandwidthUsedTotal.Collection
Instance name: Local Area Connection
Instance ID: {}

Cause

This can occur if the drivers being used for NIC teaming on the agent do not properly register in WMI.
The Base OS Management Pack (version 6.0.6958.0) contains a script that is responsible for discovering teamed adapters named Microsoft.Windows.Server.NetwokAdapter.BandwidthUsed.ModuleType.vbs. If the NIC teaming driver being used fails to properly register in WMI, when the script runs and fails to find the registered classes the script will fail and log the errors above. 
Many teaming NIC drivers also fail to register performance counters which can also be a reason why the required WMI registration is not created.

Resolution

If you experience script failures such as these, disabling NIC teaming on the agent computer will resolve the issue. The problem with the NIC registration in WMI needs to be addressed by the NIC manufacturer so that the driver correctly register itself in WMI when installed. Please contact the adapter manufacturer for more information.


This posting is provided "AS IS" with no warranties.

No comments:

Post a Comment